Ion heating boilers with heat exchanger STAFOR HE
Ion boiler with heat exchanger STAFOR HE is designed for heating systems, which is impossible to fill with special heat carrier or undesirable for various reasons (the system loses pressure and require frequent feeding, the system is heavily contaminated, etc.).
This models of the ion boilers are also recommended for parallel connection to existing heating systems that have other sources of heat.
This models of the ion boilers are also recommended for parallel connection to existing heating systems that have other sources of heat.
Advantages
Fits to any heating system
Filling of which with a special coolant (heat carrier) is not possible or desirable
Already filled with pre-regulated heat carrier
There is no need to carry out heat carrier (coolant) regulation, which reduces installation costs
The boiler is manufactured for on-floor placing and consists of:
- Metal housing with ground supports;
- Ionization and heating chamber with the ion heating element;
- Heat transfer cameras with tubular heat exchanger;
- Flow pipe connection to heating system;
- Back flow pipe to heating system;
- Heat carrier (coolant) thermal expansion compensation camera;
- Pipe for installation of automatic air vent (bleeder);
- Socket for mounting of emergency valve (over pressure);
- Fitting for drain valve;
- Fitting for mounting of control valve;
- Fitting for mounting emergency (safety) thermostat;
- Pipe for mounting of mechanical (control) thermostat;
- Block with electrical contacts and protective cover.
The boiler body is painted with anticorrosive paint and insulated with foiled heat insulation.
The boiler operates at atmospheric pressure, with natural heat carrier circulation in the boiler.
Work of ion boiler with heat exchanger is controlled by simistor (or thyristor) control panel by temperature in the chamber of heat transfer (from 0°C to +50°C).
Room temperature is controlled by a digital room thermostat-programmator Intellitherm C55. In accordance with the programmed temperature, it gives a command to turn ON or OFF main heating system circulation pump.
All automatic (control panel) and ion boiler itself operates completely silent, as the boiler work is controlled electronically, without mechanical contact.
Complete set of ion boiler STAFOR HE:
The choice of model and power of the ion boiler STAFOR HE depends on the size of the heated space and existance of DHW (hot water) boiler.
The boiler operates at atmospheric pressure, with natural heat carrier circulation in the boiler.
Work of ion boiler with heat exchanger is controlled by simistor (or thyristor) control panel by temperature in the chamber of heat transfer (from 0°C to +50°C).
Heating boiler can be used only in low temperature heating systems.
Room temperature is controlled by a digital room thermostat-programmator Intellitherm C55. In accordance with the programmed temperature, it gives a command to turn ON or OFF main heating system circulation pump.
All automatic (control panel) and ion boiler itself operates completely silent, as the boiler work is controlled electronically, without mechanical contact.
Complete set of ion boiler STAFOR HE:
- Boiler - 1 pcs.
- Automatic air vent (bleeder) - 1 pcs.
- Emergency valve - 1 pcs.
- Ball valve - 2 pcs.
- Passport of the product - 1 pcs.
- Assably and user manual - 1 pcs.
- Carrying box - 1 pcs.
- Control panel - 1 pcs.
- Mechanical thermostat - 1 pcs.
- Emergency thermostat - 1 pcs.
- Digital room thermostat-programmator - 1 pcs.
The choice of model and power of the ion boiler STAFOR HE depends on the size of the heated space and existance of DHW (hot water) boiler.
Ion boiler with heat exchanger STAFOR HE 6-9kW
Heating area from 60 m² to 112.5 m²
For use in 3P electrical power network (3 phases, 380V from 10A to 15A)
Set includes all neccessary control units and thermostats
With already filled and regulated heat carrier (coolant)
Ion boiler with heat exchanger STAFOR HE 10-20kW
Heating area from 100 m² to250 m²
For use in 3P electrical power network (3 phases, 380V from 17A to 34A)
Set includes all neccessary control units and thermostats
With already filled and regulated heat carrier (coolant)