Ion boiler STAFOR 3-5kW set
The choice of model and power of the ion boiler STAFOR depends on the size of the heated space. Below is a table on which it is possible to determine the power of the boiler and the necessary operating current.
Power accordance table
Ion boiler STAFOR power | Heating area (ceiling height till 3m and heat loss 80W on 1m²) | Work current on one phase (without home appliances) | Sum of allowed heating equipment kCal | Max heat carrier volume in system, not more than | |
Without connected sanitary water boiler | With sanitary water boiler (till 150 l) | ||||
3 kW | 37,5 m² | - | 15 A | 3,49 kCal | 24 l |
4 kW | 50 m² | - | 20 A | 4,65 kCal | 32 l |
5 kW | 62,5 m² | - | 25 A | 5,81 kCal | 40 l |
Set includes
Technical parameters
№ | Parameter | Unit | Data |
1. | Rated voltage single-phase AC In | V | 230 ± 10% |
2. | The minimum frequency of the AC | Hz | 50 |
3. | Operating current, not more than | A | 25 (cable 3*4mm²) |
4. | Nominal power | kW | 5 |
5. | Applied operating power, at a temperature of +15°C | kW | 3-5 |
6. | Heat carrier STATERM EKO E40 with conductivity not more than | µS | 205 |
7. | The maximum temperature at the outlet of the ion boiler | °C | 90 |
8. | The work temperature at the outlet of the ion boiler | °C | 70 |
9. | The size, length / height / diameter | mm | 260/95/40 |
10. | Weight, not more than | kg | 2,00 |
11. | Class of protection against electric shock | - | I |
12. | The degree of protection from moisture | - | IP44 |